DWL@DWL10000813880
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
---|---|---|---|---|---|---|
2.4.0.0 | * | 12/03/2025 | 4 Mo | EXE | AS6_HW_X20CM0985-1.exe | |
Description |
V6.0 HW Upgrade (X20CM0985-1) Revision information X20CM0985-1 Version 2.4.0.0: ID: TDYD-8347 Continuous RMS measurement after phase loss Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes Firmware: 1\46952_2.fw(200) Version 2.3.1.0: ID: 721790 Value area extension for unbalanced load constant current asymmetry (K2). A range of values from 8 to 35 (0.08 to 0.35) is possible Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_2.fw(111) Version 2.3.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 2.2.0.0: ID: 630775 Configuration parameter implemented to deactivate the evaluation of the current inputs if the generator voltages are missing This prevents a noise at the current inputs being evaluated and leading to incorrect measured values, e.g. when the generator is not connected Channel descriptionchanged: Yes Configuration description changed: Yes Firmware changed: Yes ID: 655725 Frequency measurement improved Plausibility check is more robust against saddle-shaped signals in the areaof the zero crossing. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 670145 Problem at startup of the X2X fixed X2X telegrams are no longer forwarded too early to subsequent X2X slaves during the startup phase. Thus, it is no longer possiblefor a mismatched FW to be loaded to the subsequent X2X slave. Channel description changed: No Configuration description changed: No Firmwarechanged: Yes ID: 680810 Uneven load monitoring adapted for highunbalanced load currents With unbalanced load currents above 4 times thenominal current, a fault is no longer immediately output Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 688170 additional continuous current tripping characteristics Channel description changed: No Configuration descriptionchanged: Yes Firmware changed: Yes ID: 690325 Module documentation revised Data sheet V 1.45 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_2.fw(110) Version 2.1.0.0: ID: 503770 Units adapted for display in AS Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 674135 Adaptations for Automation Studio 4.8 Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\46952_2.fw(107) Version 2.0.0.0: ID: 645125 Module documentation revised Data sheet V1.41 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 653650 If the "Over- and undervoltages check method" is configured to "Line voltages" or "Phase and line voltages", the "Over voltage of one phase" configuration is incorrectly used for generator monitoring for "Over voltage 2 of one phase". Before using this upgrade, it is therefore necessary to check the correct configuration of "Over voltage 2 of one phase" for generator monitoring. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_2.fw(107) Version 1.9.0.0: ID: 608520 X5- X3 synchronization not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 611470 Increased threshold for plausibility check of current inputs in the 1 A measuring range and thus less sensitive to interference Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_2.fw(106) Version 1.8.1.0: ID: 563885 Module documentation revised Data sheet V1.33 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(105), 1\46952_2.fw(105) Version 1.8.0.0: ID: 545065 Increase of the configurable limits of ConfigOutput11 and ConfigOutput12 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_1.fw(105), 1\46952_2.fw(105) Version 1.7.1.0: ID: 480835 Enhancement online-help Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(104), 1\46952_2.fw(104) Version 1.7.0.0: ID: 464525 The unbalance current was displayed incorrectly for current left rotating direction Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 474130 Module documentation revised Data sheet V1.21 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(104), 1\46952_2.fw(104) Version 1.6.1.0: ID: 458530 Module documentation revised Datasheet V1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(102), 1\46952_2.fw(102) Version 1.6.0.1: ID: 397120 Renewed documentation in English Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(102), 1\46952_2.fw(102) Version 1.6.0.0: ID: 378440 Configuration of the direction of rotation possible Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 378455 Extension of the monitoring functions in the generator net and mains Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 378460 Accelerate the release of the synchronization Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_1.fw(102), 1\46952_2.fw(102) Version 1.5.0.0: ID: 351350 Extension: Power measurement on 1. harmonic Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\46952_1.fw(101), 1\46952_2.fw(101) Version 1.4.2.0: ID: 306890 Bootup time of X20 system too long if module is configured but not plugged. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\46952_1.fw(100), 1\46952_2.fw(100) Version 1.4.1.0: ID: 293590 Extension to make all configuration registers readable Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(100), 1\46952_2.fw(100) |