DWL@DWL10000813880

Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
2.4.0.0 * 12/03/2025 4 Mo EXE AS6_HW_X20CM0985-1.exe
Description V6.0 HW Upgrade (X20CM0985-1)

Revision information X20CM0985-1

Version 2.4.0.0:

ID: TDYD-8347
Continuous RMS measurement after phase loss
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: Yes
Firmware: 1\46952_2.fw(200)

Version 2.3.1.0:

ID: 721790
Value area extension for unbalanced load constant current asymmetry (K2).
A range of values ​​from 8 to 35 (0.08 to 0.35) is possible
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\46952_2.fw(111)

Version 2.3.0.0:

ID:
Adaptations for Automation Studio 4.11
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 2.2.0.0:

ID: 630775
Configuration parameter implemented to deactivate the evaluation of the current inputs if the generator voltages are missing
This prevents a noise at the current inputs being evaluated and leading to incorrect measured values, e.g. when the generator is not connected
Channel descriptionchanged: Yes
Configuration description changed: Yes
Firmware changed: Yes

ID: 655725
Frequency measurement improved
Plausibility check is more robust against saddle-shaped signals in the areaof the zero crossing.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 670145
Problem at startup of the X2X fixed
X2X telegrams are no longer forwarded too early to subsequent X2X slaves during the startup phase. Thus, it is no longer possiblefor a mismatched FW to be loaded to the subsequent X2X slave.
Channel description changed: No
Configuration description changed: No
Firmwarechanged: Yes

ID: 680810
Uneven load monitoring adapted for highunbalanced load currents
With unbalanced load currents above 4 times thenominal current, a fault is no longer immediately output
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 688170
additional continuous current tripping characteristics
Channel description changed: No
Configuration descriptionchanged: Yes
Firmware changed: Yes

ID: 690325
Module documentation revised
Data sheet V 1.45
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\46952_2.fw(110)

Version 2.1.0.0:

ID: 503770
Units adapted for display in AS
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 674135
Adaptations for Automation Studio 4.8
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\46952_2.fw(107)

Version 2.0.0.0:

ID: 645125
Module documentation revised
Data sheet V1.41
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 653650
If the "Over- and undervoltages check method" is configured to "Line voltages" or "Phase and line voltages", the "Over voltage of one phase" configuration is incorrectly used for generator monitoring for "Over voltage 2 of one phase".
Before using this upgrade, it is therefore necessary to check the correct configuration of "Over voltage 2 of one phase" for generator monitoring.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\46952_2.fw(107)

Version 1.9.0.0:

ID: 608520
X5- X3 synchronization not working
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 611470
Increased threshold for plausibility check of current inputs in the 1 A measuring range and thus less sensitive to interference
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\46952_2.fw(106)

Version 1.8.1.0:

ID: 563885
Module documentation revised
Data sheet V1.33
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\46952_1.fw(105), 1\46952_2.fw(105)

Version 1.8.0.0:

ID: 545065
Increase of the configurable limits of ConfigOutput11 and ConfigOutput12
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\46952_1.fw(105), 1\46952_2.fw(105)

Version 1.7.1.0:

ID: 480835
Enhancement online-help
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\46952_1.fw(104), 1\46952_2.fw(104)

Version 1.7.0.0:

ID: 464525
The unbalance current was displayed incorrectly for current left rotating direction
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 474130
Module documentation revised
Data sheet V1.21
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\46952_1.fw(104), 1\46952_2.fw(104)

Version 1.6.1.0:

ID: 458530
Module documentation revised
Datasheet V1.20
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\46952_1.fw(102), 1\46952_2.fw(102)

Version 1.6.0.1:

ID: 397120
Renewed documentation in English
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\46952_1.fw(102), 1\46952_2.fw(102)

Version 1.6.0.0:

ID: 378440
Configuration of the direction of rotation possible
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 378455
Extension of the monitoring functions in the generator net and mains
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes

ID: 378460
Accelerate the release of the synchronization
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\46952_1.fw(102), 1\46952_2.fw(102)

Version 1.5.0.0:

ID: 351350
Extension: Power measurement on 1. harmonic
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\46952_1.fw(101), 1\46952_2.fw(101)

Version 1.4.2.0:

ID: 306890
Bootup time of X20 system too long if module is configured but not plugged.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\46952_1.fw(100), 1\46952_2.fw(100)

Version 1.4.1.0:

ID: 293590
Extension to make all configuration registers readable
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\46952_1.fw(100), 1\46952_2.fw(100)