DWL@DWL10000825654
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
---|---|---|---|---|---|---|
2.0.1.1 | * | 11/07/2025 | 662 Ko | EXE | AS6_HW_5AP5230.215C-000.exe | |
Description |
V6.0 HW Upgrade (5AP5230.215C-000) Revision information 5AP5230.215C-000 Version 2.0.1.1: ID: QCAS-2965 Updated front pictures for the display units. Channel description changed: No Configurationdescription changed: No Firmware changed: No Version 2.0.1.0: ID: 770805 Configuration changes in case that the Panel is used as Panel PC in Terminal mode. Channel description changed: No Configuration description changed: Yes Firmware changed: No Version 2.0.0.0: ID: 667250 Extensions Hypervisor from AR A4.81 USB allocation between GPOS and RTOS also possible on the Automation Panel.This requires that the appropriate hardware upgrades are used for all components (APC/PPC,AP, SDLx Receiver, SDLx Transmitter). Starting with AS 4.8 following HWX upgrades (or newer) for AP5000 are recommended, mixed operation of the current and older HWX upgrades is not recommended: APC910 system unit: V2.1.0.0 5PC900.TS17-xx: V2.1.0.0 5AC901.LSD3-00: V2.0.0.0 5AC901.LSD4-00: V2.0.0.0 xPC2100 system unit: V2.1.0.0 xPC2200 system unit: V2.0.0.0 5ACCLI01.SDL0-000: V2.0.0.0 5ACCLI01.SDL3-000: V2.0.0.0 5ACCLI03.SDL4-000: V2.0.0.0 APC3100 system unit: V2.1.0.0 5ACCLI02.SD40-000: V2.0.0.0 AP5000 panels: V2.0.0.0 AP5000 extension unit: V2.0.0.0 5DLSDL.1001-00: V2.0.0.0 5DLSD3.1001-00: V2.0.0.0 5DLSD4.1001-00: V2.0.0.0 Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 667255 EPLAN Daten implemented Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 677785 Module supervision of the Automation Panels from AR A4.81 on the AutomationPC: The supervision at the usage as display unit of aPanel PC is activ from Automation Runtime version C4.34. The supervision at the usage as display unit ofa Automation PC is activ from Automation Runtime version A4.81. In case of a missconfiguration or missing display unit the PanelPC/Automation PC is starting up in the service mode. This behavior can be configured via the configuration of the supervised option, the default is supervised = on. Channel description changed: No Configuration description changed: Yes Firmware changed: No Version 1.3.0.0: ID: 637895 Preparation to support the Panel PC 2200 Channel description changed: No Configuration description changed: Yes Firmware changed: No Version 1.2.0.0: ID: 575610 Preparation to support the SDL4 Receiver (5DLSD4.1001-00). Channel description changed: No Configuration description changed: Yes Firmware changed: No Version 1.1.0.0: ID: 552620 Bugfix for the module supervision The supervision of the 5AP1xxx.xxxx-xxx at the usage as display unit of a Panel PC isactiv from Automation Runtime version D4.34 on. In case of a missconfiguration of the display unit the Panel PC is starting up in the service mode. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 552625 Check of station number and INA Node number in terminal mode The station number and the INA node number must be identical in terminal mode. If this is not the case, an error message is outputted by Automation Studio. Channel description changed: No Configuration description changed: No Firmware changed: No Version 1.0.2.0: ID: 512450 Correction of the connectivity in the physical view With this version it is only possible to connect a suitable keypadto the regarding size of the 5AP5230.xxxx-xxx. Attention: For this hardware upgrade the Automation Studio in the version 4.2.6 is mandatory. Addionally the version of the used 5ACCKP01.xxxx-xxx has to be at least 1.0.2.0. Channel description changed: No Configuration description changed: Yes Firmware changed: No Version 1.0.0.0: ID: 465360 First version: Support beginning with Automation Studio 4.2.5.x It is recommendedto use at least the Automation Runtime version K4.10 or A4.25. Channel description changed: Yes Configuration description changed: Yes Firmware changed: No |