DWL@DWL10000255905
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
---|---|---|---|---|---|---|
1.8.0.0 | * | 23.07.2021 | 3 MB | EXE | AS4_HW_X20AI1744-3.exe | |
Popis |
V4.0 HW Upgrade (X20AI1744-3) Revision information X20AI1744-3 Version 1.8.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.7.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.6.4.0: ID: 639610 Module documentation revised Data sheet V 4.14 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9), 1\42223_3.fw(140) Version 1.6.3.0: ID: 603794 APROL: missing attributefor channel-parameter with "Sig_*" inserted Channel description changed:No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9), 1\42223_3.fw(140) Version 1.6.2.0: ID: 560900 Module documentation revised Data sheet V 4.13 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9), 1\42223_3.fw(140) Version 1.6.1.0: ID: 560900 Module documentation revised Data sheet V 4.13 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9), 1\42223_3.fw(140) Version 1.6.0.0: ID: 531185 Module documentation revised Data sheet V 4.10 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 539635 / Support ID: 400219044 Synchronization does not work In synchronous mode can it happen, the A / D converter could not synchronize to the X2X. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42223_1.fw(9), 1\42223_3.fw(140) Version 1.5.0.0: ID: 501865 Error value corrected In case "invalid value", the analog input shows the documented error value Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 501870 Module documentation revised Datasheet V 4.00 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9), 1\42223_3.fw(130) Version 1.4.0.0: ID: 496740 support HW-Variante 3 Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\42223_1.fw(9), 1\42223_3.fw(111) Version 1.3.0.0: ID: 496655 / Support ID:400196773 Modules of revision> = G0 were not backward compatible in modemultisample. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\42223_1.fw(9), 1\42223_3.fw(111) Version 1.2.3.0: ID: 474725 / Support ID: 400182966 Revised documentation Documentation revised. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9) Version 1.2.2.0: ID:429370 / Support ID: 400153065 hwx-File Correction Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9) Version 1.2.0.2: ID: 359770 englisch documentation updated Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9) Version 1.1.1.0: ID: 262745 / Support ID:400054723 Value of the X20AI1744-3 is oscillating if several X20AI1744-3are plugged side by side Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42223_1.fw(5) Version 1.1.0.0: ID: 235630 Improvement of the internal communication between ADC and I/O processor Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42223_1.fw(5) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.7.0.0 | * | 25.10.2019 | 3 MB | EXE | AS4_HW_X20AI1744-3.exe | |
Popis |
V4.0 HW Upgrade (X20AI1744-3) Revision information X20AI1744-3 Version 1.7.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.6.4.0: ID: 639610 Module documentation revised Data sheet V 4.14 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9), 1\42223_3.fw(140) Version 1.6.3.0: ID: 603794 APROL: missing attribute for channel-parameter with "Sig_*"inserted Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9), 1\42223_3.fw(140) Version 1.6.2.0: ID: 560900 Module documentation revised Data sheet V 4.13 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9), 1\42223_3.fw(140) Version 1.6.1.0: ID: 560900 Module documentation revised Data sheet V 4.13 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9), 1\42223_3.fw(140) Version 1.6.0.0: ID: 531185 Module documentation revised Data sheet V 4.10 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 539635 / Support ID: 400219044 Synchronization does not work In synchronous mode can it happen, the A / D converter could not synchronize to the X2X. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42223_1.fw(9), 1\42223_3.fw(140) Version 1.5.0.0: ID: 501865 Error value corrected In case "invalid value", the analog input shows the documented error value Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 501870 Module documentation revised Datasheet V 4.00 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9), 1\42223_3.fw(130) Version 1.4.0.0: ID: 496740 support HW-Variante 3 Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\42223_1.fw(9), 1\42223_3.fw(111) Version1.3.0.0: ID: 496655 / Support ID: 400196773 Modules of revision> = G0 were not backward compatible in mode multisample. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\42223_1.fw(9), 1\42223_3.fw(111) Version 1.2.3.0: ID: 474725 / Support ID: 400182966 Revised documentation Documentation revised. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9) Version 1.2.2.0: ID: 429370 / Support ID: 400153065 hwx-File Correction Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9) Version 1.2.0.2: ID: 359770 englisch documentation updated Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9) Version1.1.1.0: ID: 262745 / Support ID: 400054723 Value of the X20AI1744-3 is oscillating if several X20AI1744-3 are plugged side by side Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42223_1.fw(5) Version 1.1.0.0: ID: 235630 Improvement of the internal communication between ADC and I/O processor Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42223_1.fw(5) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.6.4.0 | * | 25.04.2019 | 3 MB | EXE | AS4_HW_X20AI1744-3.exe | |
Popis |
V4.0 HW Upgrade (X20AI1744-3) Revision information X20AI1744-3 Version 1.6.4.0: ID: 639610 Module documentation revised Data sheet V 4.14 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9), 1\42223_3.fw(140) Version 1.6.3.0: ID: 603794 APROL: missing attribute for channel-parameter with "Sig_*" inserted Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9), 1\42223_3.fw(140) Version 1.6.2.0: ID: 560900 Module documentation revised Data sheet V 4.13 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9), 1\42223_3.fw(140) Version 1.6.1.0: ID: 560900 Module documentation revised Data sheet V 4.13 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9), 1\42223_3.fw(140) Version 1.6.0.0: ID: 531185 Module documentation revised Data sheet V 4.10 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 539635 / Support ID: 400219044 Synchronization does not work In synchronous mode can it happen, the A / D converter could not synchronize to the X2X. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42223_1.fw(9), 1\42223_3.fw(140) Version 1.5.0.0: ID: 501865 Error value corrected In case "invalid value", the analog input shows the documented error value Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 501870 Module documentation revised Datasheet V 4.00 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9), 1\42223_3.fw(130) Version 1.4.0.0: ID: 496740 support HW-Variante 3 Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\42223_1.fw(9), 1\42223_3.fw(111) Version 1.3.0.0: ID: 496655 / Support ID: 400196773 Modules of revision> = G0 were not backward compatible in mode multisample. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\42223_1.fw(9), 1\42223_3.fw(111) Version 1.2.3.0: ID: 474725 / Support ID: 400182966 Revised documentation Documentation revised. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9) Version 1.2.2.0: ID: 429370 / Support ID: 400153065 hwx-File Correction Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9) Version 1.2.0.2: ID: 359770 englisch documentation updated Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9) Version 1.1.1.0: ID: 262745 / Support ID: 400054723 Value of the X20AI1744-3 is oscillating if several X20AI1744-3 are plugged side by side Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42223_1.fw(5) Version 1.1.0.0: ID: 235630 Improvement of the internal communication between ADC and I/O processor Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42223_1.fw(5) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.6.3.0 | * | 18.07.2018 | 3 MB | EXE | AS4_HW_X20AI1744-3.exe | |
Popis |
V4.0 HW Upgrade (X20AI1744-3) Revision information X20AI1744-3 Version 1.6.3.0: ID: 603794 APROL: missing attribute for channel-parameter with "Sig_*" inserted Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9), 1\42223_3.fw(140) Version 1.6.2.0: ID: 560900 Module documentation revised Data sheet V 4.13 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9), 1\42223_3.fw(140) Version 1.6.1.0: ID: 560900 Module documentation revised Data sheet V 4.13 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9), 1\42223_3.fw(140) Version 1.6.0.0: ID: 531185 Module documentation revised Data sheet V 4.10 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 539635 / Support ID: 400219044 Synchronization does not work In synchronous mode can it happen, the A / D converter could not synchronize to the X2X. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42223_1.fw(9), 1\42223_3.fw(140) Version 1.5.0.0: ID: 501865 Error value corrected In case "invalid value", the analog input shows the documented error value Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 501870 Module documentation revised Datasheet V 4.00 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9), 1\42223_3.fw(130) Version 1.4.0.0: ID: 496740 support HW-Variante 3 Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\42223_1.fw(9), 1\42223_3.fw(111) Version 1.3.0.0: ID: 496655 / Support ID: 400196773 Modules of revision> = G0 were not backward compatible in mode multisample. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\42223_1.fw(9), 1\42223_3.fw(111) Version 1.2.3.0: ID: 474725 / Support ID: 400182966 Revised documentation Documentation revised. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9) Version 1.2.2.0: ID: 429370 / Support ID: 400153065 hwx-File Correction Channel description changed:No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9) Version 1.2.0.2: ID: 359770 englisch documentation updated Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9) Version 1.1.1.0: ID: 262745 / Support ID: 400054723 Value of the X20AI1744-3 is oscillating if several X20AI1744-3 are pluggedside by side Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42223_1.fw(5) Version 1.1.0.0: ID: 235630 Improvement of the internal communication between ADC and I/O processor Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42223_1.fw(5) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.6.2.0 | * | 03.05.2018 | 3 MB | EXE | AS4_HW_X20AI1744-3.exe | |
Popis |
V4.0 HW Upgrade (X20AI1744-3) Revision information X20AI1744-3 Version 1.6.2.0: ID: 560900 Module documentation revised Data sheet V 4.13 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9), 1\42223_3.fw(140) Version 1.6.1.0: ID: 560900 Module documentation revised Data sheet V 4.13 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9), 1\42223_3.fw(140) Version 1.6.0.0: ID: 531185 Module documentation revised Data sheet V 4.10 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 539635 / Support ID: 400219044 Synchronization does not work In synchronous mode can it happen, the A / D converter couldnot synchronizeto the X2X. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42223_1.fw(9), 1\42223_3.fw(140) Version 1.5.0.0: ID: 501865 Error value corrected In case "invalid value", the analog input shows the documented error value Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 501870 Module documentation revised Datasheet V 4.00 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9), 1\42223_3.fw(130) Version 1.4.0.0: ID: 496740 support HW-Variante 3 Channel description changed:Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\42223_1.fw(9), 1\42223_3.fw(111) Version 1.3.0.0: ID: 496655 / Support ID: 400196773 Modules of revision> = G0 were not backward compatible in mode multisample. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\42223_1.fw(9), 1\42223_3.fw(111) Version 1.2.3.0: ID:474725 / Support ID: 400182966 Revised documentation Documentation revised. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9) Version 1.2.2.0: ID: 429370 / Support ID: 400153065 hwx-File Correction Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9) Version1.2.0.2: ID: 359770 englisch documentation updated Channeldescription changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9) Version 1.1.1.0: ID: 262745 / Support ID: 400054723 Value of the X20AI1744-3 is oscillating if several X20AI1744-3 are plugged side by side Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42223_1.fw(5) Version 1.1.0.0: ID: 235630 Improvement of the internal communication between ADC and I/O processor Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42223_1.fw(5) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.6.0.0 | * | 12.06.2017 | 3 MB | EXE | AS4_HW_X20AI1744-3.exe | |
Popis |
V4.0 HW Upgrade (X20AI1744-3) Revision information X20AI1744-3 Version 1.6.0.0: ID: 531185 Module documentation revised Data sheet V 4.10 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 539635 / Support ID: 400219044 Synchronization does not work In synchronous mode can it happen, the A / D converter could not synchronize to the X2X. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42223_1.fw(9), 1\42223_3.fw(140) Version 1.5.0.0: ID: 501865 Error value corrected In case "invalid value", the analog input shows the documented error value Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 501870 Module documentation revised Datasheet V4.00 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9), 1\42223_3.fw(130) Version 1.4.0.0: ID: 496740 support HW-Variante 3 Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\42223_1.fw(9), 1\42223_3.fw(111) Version 1.3.0.0: ID: 496655 / Support ID: 400196773 Modules of revision> = G0 were not backward compatible in mode multisample. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\42223_1.fw(9), 1\42223_3.fw(111) Version 1.2.3.0: ID: 474725 / Support ID: 400182966 Revised documentation Documentation revised. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9) Version 1.2.2.0: ID: 429370 / Support ID: 400153065 hwx-File Correction Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9) Version 1.2.0.2: ID: 359770 englisch documentation updated Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42223_1.fw(9) Version 1.1.1.0: ID: 262745 / Support ID: 400054723 Value of the X20AI1744-3 is oscillating if several X20AI1744-3 are plugged side byside Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42223_1.fw(5) Version 1.1.0.0: ID: 235630 Improvement of the internal communicationbetween ADC and I/O processor Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42223_1.fw(5) |